Charge System

Item

Servicing data

Input power

110 - 240 V AC

Rated frequency

60 Hz

Maximum rated electrical current

In normal charge

32A AC

Maximum power consumption

7.2 kVA (normal charge)

Electrical leakage detection current for control box including genuine charge cable

5 mA

EV charge mode/Connection type

Normal charge: Mode 2, Mode 3/TYPE1

Installation requirements

(information on protection against short-circuit current and equipment protection)

Applicable laws and regulations, and standards must be followed for protection measures against over-current and over-voltage.

Always make sure to install appropriate over-current protection devices to the wiring of houses and buildings.

IP level

IP44: When charge connector is connected to charge inlet

IP67 : Charging Cable

Operating temperature

On Board Charger

Ambient temperature : -30 °C (-22 °F) to 85 °C (185 °F)

coolant temperature : -30 °C (-22 °F) to 70 °C (158 °F)

Charging Cable

Ambient temperature : -30 °C (-22 °F) to 55 °C (131 °F)

Storage temperature

On Board Charger

Ambient temperature : -40 °C (-40 °F) to 85 °C (185 °F)

coolant temperature : -40 °C (-40 °F) to 85 °C (185 °F)

Charging Cable

Ambient temperature : -40 °C (-40 °F) to 80 °C (176 °F)

Applicable standards

On Board Charger

EN/IEC 61851-1, EN/IEC 61851-21, EN/IEC 61851-23, UL 2202

Charging Cable

NFPA 70, NFPA 79, SAE-J 1772, UL 62, UL 817, UL 2231-1, UL 2231-2, UL 2251, UL 2594, CSA C22.2 No.280-16

Adapters

Do not use an adapter with the plug and connector of the charging cable.

Do not use an extension cable.

Page top